архиве :)
template content :)

BOWA ARC 100 ELECTROSURGICAL UNIT

Monopolar electrosurgical unit
The BOWA ARC 100 electrosurgical unit (maximum power 100 watts) is the ideal solution for dressing rooms, "small operating rooms", ENT surgery, cosmetology, etc.

Precise monopolar cutting and efficient coagulation
Output power up to 100 watts and the desired effect on the fabric can be set step by step in 10 steps using the up and down buttons.
For monopolar cutting, Pure Cut (PureCUT) and Dry Cut (DryCUT) modes are available. The Pure CUT mode is designed for cutting without hemostasis. With the Dry CUT mode, significantly deeper coagulation effects can be achieved when tissue is cut due to the increased signal voltage.
For monopolar coagulation, Moderate and Forced modes are available. Moderate Coag is designed for less carbonation and coagulation with deeper penetration. The Forced Coag mode is best for quick and effective bleeding control with less tissue penetration.
The coagulator's universal connector can be used to connect numerous monopolar and bipolar instruments widely available on the market.
As a cosmetic coagulator, the device fully meets all requirements.
Ideal bipolar coagulation
Bipolar COAG mode provides precise tissue coagulation with a bipolar instrument such as bipolar forceps. Bipolar coagulation does not require a neutral electrode. Activation is via a footswitch connected to the ARC 100.
2-in-1: one socket for two tools
The multifunctional connector for the simultaneous connection of one bipolar and one monopolar instrument gives the user of the ARC 100 electrocoagulator an important advantage: ergonomic design combined with maximum functionality turns the ARC 100 device into one of the most economical electrosurgical systems in the class of devices with a power of up to 100 watts.
template content :)

RADIO SURGICAL EQUIPMENT RADIO SURG 2200

The radioSURG®2200 operates at a frequency of 2.2 MHz, which minimizes tissue heating in the incision area. As a result, there are practically no changes at the cellular level, and the tissue sample can be used for histological examination up to its edges.
The advantage of radiosurgery when used correctly:
Rapid wound healing;
Ease of operation without the need for pressure on the tool;
Sterile operating field;
No major bleeding.

radioSURG®2200 features:
3 waveforms (fully filtered wave, fully rectified wave and partially rectified wave);
Adjustable degree of coagulation;
Adjustable coagulation pulse duration from 0.5 to 0.45 seconds;
Cutting is done without tissue tension and pressure, which is especially important with the most even and accurate cut;
Minimal postoperative patient discomfort;
Minimizes the likelihood of cicatricial complications;
Tissue regeneration occurs at maximum speed;
The radio wave has a sterilizing effect and the electrode is always sterile;
When carrying out coagulation, the radio wave allows for the minimum time to transfer the maximum energy to the vessel and brew it without causing deep necrosis;
All electrodes are reusable.

The RadioSURG 2200 device is actively used in various fields of medicine:
general surgery;
ophthalmology;
vascular surgery;
gynecology;
pediatrics;
dental and maxillofacial surgery;
oncology;
neurosurgery;
cosmetology;
plastic and reconstructive surgery.

Operating modes of the radioSURG 2200 radiosurgical device
incision (power up to 100 W contributes to the achievement of an excellent cosmetic effect, the mode can be used for biopsy);
incision and coagulation (9 steps of power distribution from 10 to 90%, sparing effect on tissues);
coagulation (pulse (0.05 - 0.45 sec) and continuous modes of operation, adjustable power up to 90W, ensuring hemostasis or destruction of mucous membranes and tissues);
bipolar coagulation (makes it possible to coagulate a separate vessel, performed with special tweezers, pulsed or constant mode, power and degree of coagulation are adjustable).

Advantages of radioSURG 2200
The presence of separate outputs for the incision electrode, incision with coagulation and coagulation electrode with auto-activation allows you to work without resorting to replacing the electrode in the handle.
Re-adjustment of the electrode is not required - the device remembers the set operating parameters.
The radioSURG 2200 can be mounted on a convenient transport trolley with a smoke aspirator.

Synchronous operation of radioSURG 2200 and a smoke aspirator allows:
– regulate the speed of aspiration;
- effectively remove smoke, which greatly facilitates the work of the surgeon;
– adjust the operating time of the smoke aspirator after turning off the radioSURG 2200 in the range from 5 to 120 seconds;
– perform effective three-stage filtration for particles whose diameter is less than 0.014 microns (removal of odor, steam, volatile smoke particles, viruses);
– simple replacement of filters (resource from 3 to 6 months);
– maximum smoke suction power 990l/min.